SONEXvalueline™ Wall Panels Technical Specifications |
Physical Data — willtec®
| Material |
Open-cell melamine-based foam |
| Density |
0.5 to 0.7 lbs./cubic ft. (ASTM D3574-77) |
| Long-Term Service Temperature |
302 degrees F |
| Fire Resistance |
Class 1 per ASTM E 84 (all finishes)
Meets UL 1715 (willtec natural) |
| Flame Spread per ASTM E 84 |
Natural: 5
colortec™: 5
Painted: 10
Hypalon® coated: 25 |
| Smoke Density per ASTM E 84 |
Natural: 50
colortec: 90
Painted: 10
Hypalon coated: 65 |
| Microbial Growth |
Passes UL 181, section 11 |
| Fungus Resistance |
Rating #0 per ASTM G21 |
| Toxicity |
Passes University of Pittsburgh Toxicity of Smoke Emission test |
| Finishes |
Natural (white), colortec, painted or Hypalon coated*
NOTE: *20-box order minimum required for Hypalon coating |
Sound Absorption
| Finish |
Thickness |
Coefficients per ASTM C423-90a |
| |
|
125Hz |
250Hz
|
500Hz |
1kHz
|
2kHz |
4kHz
|
NRC |
Mounting
Type |
| Natural (White) |
1-1/2"
1-7/8"
2-1/2" |
0.08
0.17
0.19 |
0.08
0.17
0.19 |
0.73
1.07
1.15 |
0.94
1.15
1.21 |
0.97
1.08
1.14 |
0.89
1.10
1.20 |
0.75
0.95B
1.05 |
B
B
B |
| Painted (Charcoal, Beige, Brown, Blue, and Light Gray) |
1-1/2"
1-7/8"
2-1/2" |
0.06
0.19
0.20 |
0.08
0.17
0.19 |
0.79
1.17
1.20 |
1.02
1.21
1.19 |
1.00
1.15
1.12 |
0.98
1.13
1.12 |
0.80
1.00
1.05 |
B
B
B |
Installation Information
 |
Make sure both the panels and the
surface to which the panels are being applied are free of and dirt. If adhering to a metal
surface, use a degreaser. |
 |
Apply a line of adhesive around the perimeter
of the panel approximately 1" from the edge. |
 |
Apply a line of adhesive from opposite corners
through the center of the panel, creating an "X". |
 |
Press panel into place and hold for 5 seconds.
Then pull panel away to allow adhesive to become tacky. Lastly, press the panel back into
position and hold again for 5 seconds. |
 |
Wear clean cotton/canvas gloves for installation. |
 |
Use a sharp razor or fixed blade knife and a
metal straight edge cut panels. For best results, cut panels on flat side. |
 |
Overhead installations may require additional
adhesive and mechanical support to ensure a strong enough bond. |
|
|
|