SONEXpyramid™ Wall Panels Technical Specifications |
Physical Data — willtec®
| Material |
Open-cell melamine-based foam |
| Density |
0.5 to 0.7 lbs./cubic ft. (ASTM D3574-77) |
| Long-Term Service Temperature |
302 degrees F |
| Fire Resistance |
Class 1 per ASTM E 84 (all finishes)
Meets UL 1715 (willtec natural) |
| Flame Spread per ASTM E 84 |
Natural: 5
Painted: 10 |
| Smoke Density per ASTM E 84 |
Natural: 50
Painted: 10 |
| Microbial Growth |
Passes UL 181, section 11 |
| Fungus Resistance |
Rating 0 per ASTM G21 |
| Finishes |
Natural (white), painted |
Sound Absorption
| Finish |
Thickness |
Coefficients per ASTM C423-90a |
| |
|
125Hz |
250Hz
|
500Hz |
1kHz
|
2kHz |
4kHz
|
NRC |
Mounting
Type |
| Natural (White) |
2"
3"
4 |
0.07
0.09
0.18 |
0.25
0.37
0.44 |
0.6
0.81
0.96 |
0.94
1.01
1.14 |
0.97
1.03
1.18 |
1.08
1.07
1.19 |
0.7
0.8
0.95 |
B
B
B |
Painted
(Charcoal, Beige, Brown, Blue, Light-Grey) |
2", 3", 4" |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
B
|
Installation Information
 |
Make sure both the panels and the
surface to which the panels are being applied are free of dust and dirt. If adhering to a
metal surface, use a degreaser. |
 |
Apply a line of adhesive around the perimeter
of the panel approximately 1" from the edge. |
 |
Apply a line of adhesive from opposite corners
through the center of the panel, creating an "X". |
 |
Press panel into place and hold for 5 seconds.
Then pull panel away to allow adhesive to become tacky. Last, press the panel back into position
and hold again for 5 seconds. |
 |
Wear clean cotton/canvas gloves for installation. |
 |
Use a sharp razor or fixed-blade knife and a
metal straightedge to cut panels. For best results, cut panels on flat side. |
 |
Overhead installations may require additional
adhesive and mechanical support to ensure a strong enough bond. |
|
|
|